Search results for "Perfusion scanning"

showing 10 items of 32 documents

Magnetically labeled water perfusion imaging of the uterine arteries and of normal and malignant cervical tissue: initial experiences.

1998

Purpose: The aim of this pilot study was to evaluate a magnetically labeled water perfusion imaging technique as a non-contrast-enhanced approach to demonstrate the uterine artery, its branches, and to assess the cervical uterine blood flow in healthy volunteers and in patients with advanced uterine cervical carcinoma (FIGO IIB-IVA). Methods and Materials: Seven healthy volunteers (mean age, 29 years) and twenty-two patients (mean age, 52 years) with advanced cancer of the uterine cervix (FIGO IIB-IVA) were prospectively examined by magnetically labeled water perfusion imaging at different inversion delay times (300–900 ms). The magnetic resonance imaging (MRI) findings of all patients were…

AdultGadolinium DTPAPathologymedicine.medical_specialtyBiomedical EngineeringBiophysicsHemodynamicsContrast MediaUterine Cervical NeoplasmsPerfusion scanningCervix UteriSensitivity and Specificitymedicine.arterymedicineHumansRadiology Nuclear Medicine and imagingUterine arteryCervixAgedNeoplasm Stagingmedicine.diagnostic_testNeovascularization Pathologicbusiness.industryUterusHemodynamicsWaterMagnetic resonance imagingBlood flowArteriesMiddle AgedImage EnhancementMagnetic Resonance ImagingPerfusionmedicine.anatomical_structureDynamic contrast-enhanced MRIFemaleNuclear medicinebusinessPerfusionBlood Flow VelocityMagnetic resonance imaging
researchProduct

Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods

2015

Arterial spin labeling (ASL) is an emerging MRI technique for non-invasive measurement of cerebral blood flow (CBF). Compared to invasive perfusion imaging modalities, ASL suffers from low sensitivity due to poor signal-to-noise ratio (SNR), susceptibility to motion artifacts and low spatial resolution, all of which limit its reliability. In this work, the effects of various state of the art image processing techniques for addressing these ASL limitations are investigated. A processing pipeline consisting of motion correction, ASL motion correction imprecision removal, temporal and spatial filtering, partial volume effect correction, and CBF quantification was developed and assessed. To fur…

AdultMaleComputer scienceCognitive Neurosciencecerebral blood flowPartial volumePerfusion scanningImage processingSignal-To-Noise RatioYoung AdultImage Processing Computer-Assistedspin labelingHumansreproducibilityImage resolutionReproducibilitySpatial filterbusiness.industrymultiphase pseudo-continuous arterialBrainReproducibility of ResultsSite-directed spin labelingImage EnhancementMagnetic Resonance Imagingarterial spin labelingNeurologyCerebral blood flowArterial spin labelingFemaleSpin Labelsperfusion MRIArtifactsNuclear medicinebusinesstest–retestBiomedical engineeringNeuroImage
researchProduct

Usefulness of quantitative peritumoural perfusion and proton spectroscopic magnetic resonance imaging evaluation in differentiating brain gliomas fro…

2016

Objectives The purpose of our study was to evaluate whether peritumoural perfusion weighted and proton spectroscopic magnetic resonance imaging can be used in differentiating between primary gliomas and solitary metastases. Methods Ten low-grade gliomas, eight high-grade gliomas and 10 metastases were prospectively evaluated with magnetic resonance imaging, dynamic susceptibility contrast enhanced perfusion imaging and single-voxel proton magnetic resonance spectroscopy before surgical resection or stereotactic biopsy. Maximal relative cerebral blood volume values were calculated drawing three regions of interest of 2 cm2 in the non-enhancing peritumoural areas. Maximal relative cerebral bl…

AdultMaleMagnetic Resonance SpectroscopyStereotactic biopsyBrain TumorsPerfusion scanningSensitivity and Specificity030218 nuclear medicine & medical imagingDiagnosis DifferentialWhite matter03 medical and health sciences0302 clinical medicineGliomaImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingmedicine.diagnostic_testBrain Neoplasmsbusiness.industryperfusion weighted magnetic resonance imagingMagnetic resonance spectroscopic imagingMagnetic resonance imagingGliomaGeneral MedicineMiddle AgedPerfusion-Weighted Magnetic Resonance Imagingmedicine.diseaseMagnetic Resonance Imagingmedicine.anatomical_structureBrain gliomaFemaleNeurology (clinical)businessNuclear medicinePerfusion030217 neurology & neurosurgerybrain metastaseThe Neuroradiology Journal
researchProduct

FAIR and dynamic susceptibility contrast-enhanced perfusion imaging in healthy subjects and stroke patients.

2002

Purpose To compare dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI) and the flow-sensitive alternating inversion recovery (FAIR) technique for measuring brain perfusion. Materials and Methods We investigated 12 patients with acute stroke, and 10 healthy volunteers with FAIR and DSC maps of regional cerebral blood volume (rCBV), mean transit time (MTT), and regional cerebral blood flow (rCBF). Results In volunteers good gray/white-matter contrast was observed in FAIR, rCBF, and rCBV maps. Regions with high signal intensities in FAIR matched well with high values of rCBV and rCBF. In ischemic stroke patients a high correlation (r = 0.78) of the ipsi- to contralate…

AdultMaleStroke patientContrast MediaPerfusion scanningmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingAgedmedicine.diagnostic_testbusiness.industryHealthy subjectsMagnetic resonance imagingMiddle AgedMagnetic Resonance ImagingStrokeCerebral blood volumeCerebral blood flowRegional Blood FlowCase-Control StudiesCerebrovascular CirculationAcute DiseaseFemaleNuclear medicinebusinessPerfusionDynamic susceptibilityJournal of magnetic resonance imaging : JMRI
researchProduct

Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques

2008

Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …

AdultMalemedicine.diagnostic_testPhantoms Imagingbusiness.industryImage qualityPerfusion scanningPulse sequenceBlood flowMagnetic Resonance ImagingMyocardial perfusion imagingContrast mediumCoronary CirculationHealthy volunteerscardiovascular systemmedicineImage noiseHumansFemaleRadiology Nuclear Medicine and imagingNuclear medicinebusinessMathematicsJournal of Magnetic Resonance Imaging
researchProduct

Detection of intracranial circulatory arrest in brain death using cranial CT-angiography.

2011

Background and purpose Computed tomographic-angiography (CT-A) is becoming more accepted in detecting intracranial circulatory arrest in brain death (BD). An international consensus about the use and the parameters of this technique is currently not established. We examined intracranial contrast enhancement in CT-A after clinically confirmed BD, compared the results with electroencephalography (EEG) and Transcranial Doppler Ultrasonography (TCD) findings and developed a commonly applicable CT-A protocol. Methods Prospective, monocentric study between April 2008 and October 2011. EEG, TCD and CT-A were performed in 63 patients aged between 18 and 88 years (mean, 55 years) who fulfilled clini…

AdultMalemedicine.medical_specialtyBrain DeathTomography Scanners X-Ray ComputedAdolescentUltrasonography Doppler TranscranialPerfusion scanningElectroencephalographyYoung AdultmedicineHumansCerebral perfusion pressureAgedRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryBrainElectroencephalographyVenous bloodBlood flowMiddle AgedNeurologyAnesthesiaCirculatory systemAngiographyBlood VesselsFemaleNeurology (clinical)NeurosurgeryRadiologybusinessMagnetic Resonance AngiographyEuropean journal of neurology
researchProduct

Myocardial Perfusion and Fractional Flow Reserve

2013

Myocardial CT perfusion imaging is a rapidly evolving technology that allows assessment of the functional significance of potentially obstructive coronary stenosis. The opportunity for quantification of myocardial perfusion is the greatest potential advantage of CT compared with other perfusion techniques. On the other hand, fractional flow reserve during coronary angiography provides a functional assessment of coronary lesions identified with this modality. Recently, a non-invasive method for estimating fractional flow reserve, based on coronary CT angiography has been introduced. Nevertheless, at present neither CT perfusion nor CT FFR are ready for widespread use in clinical routine.

Coronary angiographymedicine.medical_specialtymedicine.diagnostic_testbusiness.industryCoronary ct angiographyPerfusion scanningCoronary stenosisFractional flow reserveMyocardial perfusion imagingInternal medicineCardiologymedicineFunctional significancebusinessPerfusion
researchProduct

Non invasive blood flow measurement in cerebellum detects minimal hepatic encephalopathy earlier than psychometric tests

2013

AIM: To assess whether non invasive blood flow measurement by arterial spin labeling in several brain regions detects minimal hepatic encephalopathy. METHODS: Blood flow (BF) was analyzed by arterial spin labeling (ASL) in different brain areas of 14 controls, 24 cirrhotic patients without and 16 cirrhotic patients with minimal hepatic encephalopathy (MHE). Images were collected using a 3 Tesla MR scanner (Achieva 3T-TX, Philips, Netherlands). Pulsed ASL was performed. Patients showing MHE were detected using the battery Psychometric Hepatic Encephalopathy Score (PHES) consisting of five tests. Different cognitive and motor functions were also assessed: alterations in selective attention we…

Liver CirrhosisMaleCerebellumPathologyPerfusion scanningArterial spin labellingCognitionCerebellumAttentionHepatic encephalopathyCyclic GMPmedicine.diagnostic_testGastroenterologyGeneral MedicineBlood flowMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structurePredictive value of testsCerebrovascular CirculationFemaleInflammation MediatorsBlood Flow Velocitymedicine.medical_specialtyPsychometricsPerfusion ImagingMinimal hepatic encephalopathymacromolecular substancesMotor ActivityNitric OxideAmmoniaPredictive Value of TestsRetrospective StudymedicineHumansAgedRetrospective Studiesbusiness.industryNon invasiveMagnetic resonance imagingBlood flowmedicine.diseaseEarly DiagnosisRegional Blood FlowHepatic EncephalopathyStroop TestbusinessPsychometric testsBiomarkersNeurological impairment
researchProduct

MRI of the pulmonary parenchyma.

1999

Imaging of the pulmonary parenchyma represents a unique challenge for MRI. Limited signal is caused by low proton density, susceptibility artifacts, and physiological motion (cardiac pulsation, respiration). Recently, further improvements in MRI techniques have widened the potential for investigations of pulmonary parenchymal disease. These include very short echo times, ultrafast turbo-spin-echo acquisitions, projection reconstruction technique, breathhold imaging, ECG triggering, contrast agents (perfusion imaging, aerosols), sodium imaging, hyperpolarized noble gas imaging, and oxygen enhancement. By using widely available techniques, MRI is helpful in the assessment of (a) acute alveoli…

Lung DiseasesChronic bronchitismedicine.medical_specialtyPulmonary FibrosisContrast MediaAtelectasisPerfusion scanningPulmonary EdemaSensitivity and SpecificityDiagnosis DifferentialMedicineHumansRadiology Nuclear Medicine and imagingLungNeuroradiologyBronchiectasisLungbusiness.industryGeneral MedicinePneumoniamedicine.diseasePulmonary edemaImage EnhancementMagnetic Resonance ImagingPneumoniamedicine.anatomical_structureInjections IntravenousRadiologybusinessPulmonary EmbolismEuropean radiology
researchProduct

Contrast-enhanced MRI of the lung

2000

The lung has long been neglected by MR imaging. This is due to unique intrinsic difficulties: (1) signal loss due to cardiac pulsation and respiration; (2) susceptibility artifacts caused by multiple air-tissue interfaces; (3) low proton density. There are many MR strategies to overcome these problems. They consist of breath-hold imaging, respiratory and cardiac gating procedures, use of short repetition and echo times, increase of the relaxivity of existing spins by administration of intravenous contrast agents, and enrichment of spin density by hyperpolarized noble gases or oxygen. Improvements in scanner performance and frequent use of contrast media have increased the interest in MR ima…

Lung DiseasesMalemedicine.medical_specialtyLung NeoplasmsContrast MediaPerfusion scanningSensitivity and SpecificityVentilation/perfusion ratiomedicineHumansRadiology Nuclear Medicine and imagingVascular DiseasesNeoplasm StagingLungbusiness.industryRespiratory diseaseInterstitial lung diseaseGeneral Medicinemedicine.diseaseMagnetic Resonance ImagingPulmonary embolismContrast mediumCarcinoma Bronchogenicmedicine.anatomical_structureBreathingFemaleRadiologyPulmonary EmbolismPulmonary VentilationbusinessMagnetic Resonance AngiographyEuropean Journal of Radiology
researchProduct